Combined the two LSM 700 Confocal Microscopes (Zeiss) have the following features:
- Four lasers: 405, 488, 555 and 639 nm.
- Four objectives: 10X, 20X, 63X oil, and 100X oil.
- Plus LSM T-PMT detector to capture DIC images.
- Zen 2009 software is used for image capture and analysis.
Services provided:
- Hands-on training on Confocal Microscope system usage.
- Assistance on Confocal Microscope experimental design.
- Additional services provided upon request.
Product Website:
- LSM 700 Brochure
- Access and download the free software ZEN LITE for Laser Scanning Microscopes; Zeiss courtesy.
Related Content:
- Apoptosis Slide Show
- Microscope Image Show
- Apoptosis/Necrosis detected with YO-PRO1 and Propidium Iodide Video
BD Pathway Bioimager System
(BD Biosciences)
This multiwell (96 and 384) plate reader confocal microscope system has stationary stage with movable optics and it is assisted with Attovison software to capture images and data analysis. The system is equipped with environmental control chamber (37ºC, 5% CO2) and liquid handling system. Light from two mercury lamps provides illumination from 360 nm to 700 nm. Also, this Bioimager provides the ability to capture bright-field images that can be overlaid onto fluorescent images. The laser-based autofocus capability of the BD Pathway systems enables rapid acquisition of high-quality images. Four objectives (4X, 10X, 20X and 40X) are available to capture images in an ample variety of montages (contiguous frames and confocal Z stack acquisition mode).
Services provided:
Hands-on training on Bioimager system usage.
Assistance on Bioimager experimental design.
Additional services provided upon request.
Product Website:
Related Content:
Flow Cytometry Analyzer
(Cytomic FC500; Beckman Coulter)
The Cytomic FC 500 System offers automated tube-based acquisition for cell-based
Assays. This system is equipped with the following two lasers: an Argon ion laser (488nm) and
a Red solid state HeNe laser (631nm). Photodiodes also detect Forward Scatter (FS) and Side Scatter (SS) signals.
The following range of emissions can be detected:
525 nm/40 | (FL1; FITC, fluorescein isothiocyanate; Alexa Fluor488; GFP, green fluorescence protein; CFSE, carboxyfluorescein diacetate; Calcein) |
575 nm/40 | (FL2; PE, phycoerythrin; PI, propidium iodide) |
620 nm/20 | (FL3; PE, phycoerythrin; TexasRed; PI, Propidium Iodide) 675 nm/40 (FL4; APC, allophycocyanin; PE-Cy5, conjugate that combines phycoerythrin and cyanine dye 5; Alexa Fluor 647) |
755 nm/40 | (FL5; PE-Cy7, phycoerythrin conjugated with cyanine dye 7; APC-Cy7, conjugate of allophycocyanin and cyanine dye 7; APC-Alexa Fluor750, allophycocyanin conjugated to Alexa flour750. |
Services provided:
Hands-on training on flow cytometer system usage
Assistance on flow cytometry experimental design.
Additional services provided upon request.
Product Website:
Automated Pipetting System
(epMotion 5070; Eppendorf)
The system is useful to perform serial dilutions, reagent distribution, sample dispensing from tubes to plates, or from plate to plate. This system can use tissue culture or PCR plates with 96 and 384 wells.
Services provided:
Hands-on training on Automated Pipetting System Assistance on pipetting experimental design.
Additional services provided upon request.
Product Website:
epMotion 5070 Operating Manual
Flow Cytometer and Sorter
Flow Cytometer and Sorter EPICS ALTRA
This cell sorter has the capability to analyze and sort cells using up to 6 colors simultaneously at data rates up to 10,000 cells per second. The system is very useful in separating cells with distinct fluorescence signals from a mixed cell population and to enrich selected cells with uniform fluorescence intensities.
Services provided:
The EPICS ALTRA cell sorter is operated exclusively by Core Facility personnel.
Assistance on flow cytometry experimental design.
Note: Appointment with Core personnel is absolutely necessary previously to request any cell sorting service.